Home blood pressure (BP) monitoring serves as a practical method to detect changes in BP instead of ambulatory BP monitoring in hemodialysis patients. To evaluate the relationship of reduction in home BP compared to interdialytic ambulatory BP measurements we analyzed the data from the dry-weight reduction in hypertensive hemodialysis patients (DRIP) trial in which 100 patients had their dry weight probed based on clinical sign and symptoms and 50 patients served as controls. We measured home BP 3 times a day for 1 week using a validated oscillometric monitor on 3 occasions at 4-week intervals after randomization. Changes from baseline in home, predialysis BP and postdialysis BP were compared to interdialytic 44-hour ambulatory BP. Home and ambulatory BP monitoring was available in 141 of 150 (94%) patients. Predialysis systolic BP was not as sensitive as ambulatory BP in detecting change in BP with dry-weight reduction. Whereas postdialysis BP was capable of detecting an improvement in systolic BP in response to probing dry weight, by itself it does not provide evidence that change in postdialysis BP persists over the interdialytic period. Home BP reliably detected changes in ambulatory BP, albeit with less sensitivity at 4 weeks. However, at 4 and at 8 weeks, changes in home systolic BP were most strongly related to changes in interdialytic ambulatory systolic BP compared to predialysis and postdialysis BP. The reproducibility of BP measurements followed the order home > ambulatory >> predialysis > postdialysis. These data provide support for the use of home BP monitoring for the management of hypertension in hemodialysis patients.

1.
Thompson AM, Pickering TG: The role of ambulatory blood pressure monitoring in chronic and end-stage renal disease. Kidney Int 2006;70:1000–1007.
2.
Lazar AE, Smith MC, Rahman M: Blood pressure measurement in hemodialysis patients. Semin Dial 2004;17:250–254.
3.
Agarwal R: Assessment of blood pressure in hemodialysis patients. Semin Dial 2002;15:299–304.
4.
K/DOQI clinical practice guidelines for cardiovascular disease in dialysis patients. Am J Kidney Dis 2005;45:S1–S153.
5.
Davenport A, Cox C, Thuraisingham R: Achieving blood pressure targets during dialysis improves control but increases intradialytic hypotension. Kidney Int 2007;73:759–764.
6.
Agarwal R, Peixoto AJ, Santos SF, Zoccali C: Pre- and postdialysis blood pressures are imprecise estimates of interdialytic ambulatory blood pressure. Clin J Am Soc Nephrol 2006;1:389–398.
7.
Agarwal R, Metiku T, Tegegne GG, Light RP, Bunaye Z, Bekele DM, Kelley K: Diagnosing hypertension by intradialytic blood pressure recordings. Clin J Am Soc Nephrol 2008;3:1364–1372.
8.
Pickering TG, Miller NH, Ogedegbe G, Krakoff LR, Artinian NT, Goff D: Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society of Hypertension, and Preventive Cardiovascular Nurses Association. Hypertension 2008;52:10–29.
9.
Parati G, Stergiou GS, Asmar R, Bilo G, de Leeuw P, Imai Y, Kario K, Lurbe E, Manolis A, Mengden T, O’Brien E, Ohkubo T, Padfield P, Palatini P, Pickering T, Redon J, Revera M, Ruilope LM, Shennan A, Staessen JA, Tisler A, Waeber B, Zanchetti A, Mancia G: European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring. J Hypertens 2008;26:1505–1526.
10.
Agarwal R: Role of home blood pressure monitoring in hemodialysis patients. Am J Kidney Dis 1999;33:682–687.
11.
Agarwal R, Andersen MJ, Bishu K, Saha C: Home blood pressure monitoring improves the diagnosis of hypertension in hemodialysis patients. Kidney Int 2006;69:900–906.
12.
Agarwal R, Brim NJ, Mahenthiran J, Andersen MJ, Saha C: Out-of-hemodialysis-unit blood pressure is a superior determinant of left ventricular hypertrophy. Hypertension 2006;47:62–68.
13.
Alborzi P, Patel N, Agarwal R: Home blood pressures are of greater prognostic value than hemodialysis unit recordings. Clin J Am Soc Nephrol 2007;2:1228–1234.
14.
Agarwal R, Andersen MJ: Prognostic importance of clinic and home blood pressure recordings in patients with chronic kidney disease. Kidney Int 2006;69:406–411.
15.
Bobrie G, Chatellier G, Genes N, Clerson P, Vaur L, Vaisse B, Menard J, Mallion JM: Cardiovascular prognosis of ‘masked hypertension’ detected by blood pressure self-measurement in elderly treated hypertensive patients. JAMA 2004;291:1342–1349.
16.
Ohkubo T, Imai Y, Tsuji I, Nagai K, Kato J, Kikuchi N, Nishiyama A, Aihara A, Sekino M, Kikuya M, Ito S, Satoh H, Hisamichi S: Home blood pressure measurement has a stronger predictive power for mortality than does screening blood pressure measurement: a population-based observation in Ohasama, Japan. J Hypertens 1998;16:971–975.
17.
Agarwal R, Alborzi P, Satyan S, Light RP: Dry-weight reduction in hypertensive hemodialysis patients. A randomized, controlled trial. Hypertension 2009;53:500–507.
18.
Charra B, Laurent G, Chazot C, Calemard E, Terrat JC, Vanel T, Jean G, Ruffet M: Clinical assessment of dry weight. Nephrol Dial Transplant 1996;11(suppl 2):16–19.
19.
Jaeger JQ, Mehta RL: Assessment of dry weight in hemodialysis: an overview. J Am Soc Nephrol 1999;10:392–403.
20.
Singer JD, Willett JB: Applied Longitudinal Data Analysis: Modeling Change and Event Occurrence. Oxford, Oxford University Press, 2003.
21.
Holden JE, Kelley K, Agarwal R: Analyzing change: a primer on multilevel models with applications to nephrology. Am J Nephrol 2008;28:792–801.
22.
Pickering TG, Shimbo D, Haas D: Ambulatory blood-pressure monitoring. N Engl J Med 2006;354:2368–2374.
23.
Peixoto AJ, White WB: Ambulatory blood pressure monitoring in chronic renal disease: technical aspects and clinical relevance. Curr Opin Nephrol Hypertens 2002;11:507–516.
24.
Kelley K, Light RP, Agarwal R: Trended cosinor change model for analyzing hemodynamic rhythm patterns in hemodialysis patients. Hypertension 2007;50:143–150.
25.
Agarwal R, Andersen MJ, Light RP: Location not quantity of blood pressure measurements predicts mortality in hemodialysis patients. Am J Nephrol 2007;28:210–217.
26.
Agarwal R, Light RP: Arterial stiffness and interdialytic weight gain influence ambulatory blood pressure patterns in hemodialysis patients. Am J Physiol Renal Physiol 2007;294:F303–F308.
27.
Peixoto AJ, Santos SF, Mendes RB, Crowley ST, Maldonado R, Orias M, Mansoor GA, White WB: Reproducibility of ambulatory blood pressure monitoring in hemodialysis patients. Am J Kidney Dis 2000;36:983–990.
28.
Kauric-Klein Z, Artinian N: Improving blood pressure control in hypertensive hemodialysis patients. CANNT J 2007;17:24–26.
29.
Deziel C, Bouchard J, Zellweger M, Madore F: Impact of hemocontrol on hypertension, nursing interventions, and quality of life: a randomized, controlled trial. Clin J Am Soc Nephrol 2007;2:661–668.
30.
Ishikawa J, Carroll DJ, Kuruvilla S, Schwartz JE, Pickering TG: Changes in home versus clinic blood pressure with antihypertensive treatments: a meta-analysis. Hypertension 2008;52:856–864.
31.
Agarwal R: How should hypertension be assessed and managed in hemodialysis patients? Home BP, not dialysis unit BP, should be used for managing hypertension. Semin Dial 2007;20:402–405.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.